What Is The Fire Rating Of 1/2 Inch Drywall?

How thick is a 2 hour fire rated wall?

3 1/5 inchesThe fire-resistance rating of concrete masonry walls depends on the type of aggregate used in the units.

A 2-hour rating can be achieved by a wall with an equivalent thickness of as little as 3 1/5 inches when expanded slag or pumice is used or 4 1/2 inches when siliceous gravel is used as the aggregate..

What is a 4 hour fire rated wall?

Combined, the level of protection against a fire increases significantly. To create 4-hour fire rated protection, things like cold-formed steel clips, gypsum board, and corner beads are included. At this level of protection, the thickness of the gypsum and the casing attachment meet tight specifications.

What is fire tape for drywall?

This tape, as the name suggests, is a fire-resistant construction material that is designed to slow or prevent household fires. Once you have measured, cut and hung your fire-resistant drywall, it must be taped and at least one coat of joint compound applied for the proper installation and fire rating.

Is regular drywall fire rated?

Drywall is relatively fire resistant. It’s composed of gypsum pressed between two sheets of thick paper. Gypsum is a soft mineral that by itself is not flammable.

Does 1/2 drywall have a fire rating?

Why Fireproof Drywall Is Fire-Rated If a conventional 1/2-inch thick sheet of drywall will stand up to 30 minutes of fire, then the added 1/8-inch found in the Type X drywall, along with its other properties, will double your margin of safety to 60 minutes.

Are concrete blocks fire resistant?

Concrete Blocks are a great choice for the construction of your next masonry project. Concrete Block construction provides durability,fire resistance and thermal mass which adds to energy efficiency. Concrete block also provide high resistance to sound penetration.

Is drywall a combustible material?

Because the Building Subcode allows such “composite” materials, gypsum wallboard can be considered noncombustible as defined by the Building Subcode. … Therefore remember, under the Mechanical Subcode, gypsum wallboard is classified as a combustible material.

Is all drywall fire resistant?

Although all drywall is fire resistant to a degree, type-X and type-C drywall are designed specifically to be used in fire-rated assemblies. These products help to contain fire in the area of its origin much better than regular drywall.

Does drywall thickness matter?

Standard Walls The most common thickness of drywall used in residential interior construction is 1/2 inch. This material is recommended for walls with studs placed 16 inches on center. If the wall studs are placed 24 inches on center, a 5/8-inch drywall is recommended.

What makes a 1 hour fire rated wall?

According to the book “Commercial Drafting and Detailing,” a typical one-hour fire rated wall consists of 2×4 studs spaced 16 inches from the center of one stud to the center of the next, covered by 5/8-inch, type X gypsum board. Type X gypsum board is wallboard to which non-combustible fibers have been added.

What’s the fire rating on 5/8 drywall?

1 hourNorm Abram replies: The 5/8-inch, “fire-code” drywall (called Type X) increases a wall’s fire rating to a minimum of 1 hour, from the 30-minute rating for standard ½-inch drywall. And it’s not just thickness that makes the difference.

How much does 1 hour of drywall fire rating cost?

Fire-resistant Drywall Type X – $9/panel. Holds backfire for one hour. Type C – $12/panel. Rated for three hours in ceilings and four hours in walls.

What is the building code for drywall?

Field: About 16 inches apart Both the International Residential Code (IRC) and USG, the manufacturer of Sheetrock, say that maximum field screw spacing for wall drywall is 16 inches. Some builders like to space fasteners tighter than that, so they go down to 12 inches.

What makes a fire rated wall?

A true fire-rated wall extends through the roof between sides of a building, such as a townhouse or apartment complex. It also extends downward through the floor. In essence, it is designed and certified to prevent fire from spreading through a building in the event that one ignites on one side.

What makes a 2 hour fire rated wall?

Gypsum Board: Two (2) hour rated walls have two (2) layers of 5/8″ Type ‘X’ gypsum wallboard panels on each side of the steel studs. The “Fire Tape” product would be used as an alternative to conventional joint tape in specific systems when: 3.

Where is fire rated sheetrock required?

Fire rated drywall is typically found on attached garage walls and ceilings that are adjacent to the main living area of the home. For commercial buildings, fire rated gypsum drywall is specified for most of the building walls and ceilings to meet building code requirements for fire partitions and assemblies.